Resources & downloads

All product catalogues and certificates in one list. Project-specific test reports are shared at the quoting stage.

Catalogues & certificates

Addressable Fire Alarm Control PanelProduct catalogue (PDF)Download ↓
Addressable Fire Alarm Control PanelEN 54 certificate (PDF)Download ↓
Optical Smoke DetectorDatasheet (PDF)Download ↓
Optical Smoke DetectorEN 54 certificate (PDF)Download ↓
Clean Agent Suppression System (FK-5-1-12 / HFC-227ea)System catalogue (PDF)Download ↓
Clean Agent Suppression System (FK-5-1-12 / HFC-227ea)Certificate (PDF)Download ↓
Blast Damper (Explosion Pressure Resistant)Product catalogue (PDF)Download ↓
Blast Damper (Explosion Pressure Resistant)Test report (PDF)Download ↓
Fire-Resistant Steel Door (EI60 / EI120)Product catalogue (PDF)Download ↓
Fire-Resistant Steel Door (EI60 / EI120)Certificate (PDF)Download ↓
Fire/Blast-Resistant Window SystemProduct catalogue (PDF)Download ↓
Fire/Blast-Resistant Window SystemCertificate (PDF)Download ↓
Beam Smoke DetectorDatasheet (PDF)Download ↓
Beam Smoke DetectorCertificate (PDF)Download ↓
Gas Detector (LEL / Toxic)Datasheet (PDF)Download ↓
Gas Detector (LEL / Toxic)Certificate (PDF)Download ↓
Sprinkler System (Wet / Dry / Pre-action)System catalogue (PDF)Download ↓
Sprinkler System (Wet / Dry / Pre-action)Certificate (PDF)Download ↓
Foam Suppression SystemSystem catalogue (PDF)Download ↓
Foam Suppression SystemCertificate (PDF)Download ↓
In-Cabinet Automatic SuppressionProduct catalogue (PDF)Download ↓
In-Cabinet Automatic SuppressionCertificate (PDF)Download ↓
Fire & Smoke Damper (EI120)Product catalogue (PDF)Download ↓
Fire & Smoke Damper (EI120)Certificate (PDF)Download ↓

Technical notes

Maintenance intervals for fire systems

Detector tests and panel checks follow regulation and manufacturer calendars; gaseous systems add periodic cylinder weighing/pressure checks and room-integrity verification. A maintenance contract consolidates these calendars into one plan with a report per visit.

Room integrity testing for clean-agent systems

Holding the design concentration depends on enclosure tightness. A door-fan test measures the leakage area and the retention-time calculation is verified against it. The test is repeated at commissioning and after room modifications.

Pressure class in blast damper selection

Selection is based on the scenario pressure (peak and duration), duct section and allowable leakage. A wrong pressure class either trips ventilation early or lets the wave through — selection is therefore always a project calculation.

Standards guide

EN 54Fire detection and alarm systems — component and system requirements
NFPA 72 / 13 / 11 / 2001Design rules for alarm, sprinkler, foam and clean-agent suppression
EN 15004 · ISO 14520Design and installation rules for gaseous suppression systems
EN 1634-1 · EN 13501Fire-resistance testing and classification of doors and partitions
EN 15650 · EN 1366Fire and smoke damper test and product standards
BYKHYTurkish regulation on fire protection of buildings